Laboratory report · 26027869-001
Sample: Watson Nutrition: Magnesium (120 Kapseln)
Sample marking: Charge: 96467; MHD: 28.05.2028
Batch in report: 96467
Current retail batch unknown
Document date: 2026-06-15
Test period: 2026-06-08 – 2026-06-15
Product and pack match: The retained current manufacturer page selects Shopify variant 50787399565627, explicitly 120 capsules and 200 mg magnesium per four capsules. The report explicitly names Watson Magnesium (120 Kapseln), submitted batch 96467; the associated nutrition report photo appendix shows the same 120-capsule pack, four-capsule declaration and ordered ingredients. This establishes product/formulation/pack association for the tested sample. The batch currently supplied to customers is not established; no sample capsule mass is promoted to current retail net mass.
Commissioner according to source: Beyond Food GmbH
Source conclusion (within its stated scope): GBA describes the microbiological findings as unremarkable and concludes compliance for this sample's lead, cadmium and mercury results against its stated maxima. This does not establish a verdict for other analytes or current retail batches.
Source observation and document identity
Source observed: 2026-10-17T18:01:39.221Z
Content fetched: 2026-10-17T18:01:39.221Z
Page 1
SHA-256: f7f2882e0a7315fc532085d814fc54ea2a2fb4dc4778b61dda05261e1cf22d24
Gesamtkeimzahl
The measurement comes from the tested sample. Declared and measured amounts are directly comparable only with the same unit and basis.
- Result as reported
- 2,0 ·10^1
- Unit and basis
- KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram
- Method
- DIN EN ISO 4833-2: 2022-05
- Source location
- Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Source conclusion: The source marks this small count as detected only and statistically non-significant (footnote on page 3). Original scientific notation is retained; it is not promoted to an exact platform colony count.
Not assessed
A qualitative result has no numeric assessment here.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Hefen
This test examines microorganisms in the sample. Its result applies to that sample and the stated test method.
- Result as reported
- <10
- Unit and basis
- KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram
- Method
- BIOKAR Diagnostics, Symphony-Agar BM20208/BM19108:2022-11; validated against EN ISO 21527-1/-2:2008-11
- Source location
- Page 2
Reporting limit: 10 KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram · Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Schimmelpilze
This test examines microorganisms in the sample. Its result applies to that sample and the stated test method.
- Result as reported
- <10
- Unit and basis
- KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram
- Method
- BIOKAR Diagnostics, Symphony-Agar BM20208/BM19108:2022-11; validated against EN ISO 21527-1/-2:2008-11
- Source location
- Page 2
Reporting limit: 10 KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram · Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Enterobacteriaceae
This test examines microorganisms in the sample. Its result applies to that sample and the stated test method.
- Result as reported
- <10
- Unit and basis
- KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram
- Method
- Biomerieux, Rebecca-Agar AEB520020/AEB150022:2020-09; validated against ISO 21528-2:2017-07
- Source location
- Page 2
Reporting limit: 10 KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram · Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
E. coli
This test examines microorganisms in the sample. Its result applies to that sample and the stated test method.
- Result as reported
- <10
- Unit and basis
- KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram
- Method
- Biomerieux, Rebecca-Agar AEB520020/AEB150022:2020-09; validated against ISO 16649-2:2001-07
- Source location
- Page 2
Reporting limit: 10 KBE/g · KBE/g of submitted finished-product sample, batch 96467; colony-forming units per gram · Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Salmonellen
This test examines microorganisms in the sample. Its result applies to that sample and the stated test method.
- Result as reported
- negativ
- Unit and basis
- /25 g · Qualitative Salmonella test on 25 g of the submitted sample, batch 96467; no zero count or whole-bottle inference
- Method
- DIN EN ISO 6579-1:2020-08
- Source location
- Page 2
Decision rule: Source rule m assesses microbiological conformity without other analytical quantities. No numeric criterion is supplied in this report. · Page 3
Measurement uncertainty: not recorded
Not assessed
A qualitative result has no numeric assessment here.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Blei
This measures a potential contaminant. Concentration, unit, detection limit and the applicable product category matter.
- Result as reported
- <0,020
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, ICP-MS:2010-04
- Source location
- Page 2
Reporting limit: 0.02 mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion · Page 2
Stated criterion: Höchstgehalt 3 mg/kg · mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
Applicability: reviewed · Attributed only to the original report's stated category and submitted sample. No independent current-law, other-product or current-retail-batch claim.
Criterion source ↗Source observation and document identity
Source observed: 2026-10-17T18:01:39.221Z
Content fetched: 2026-10-17T18:01:39.221Z
Page 2
SHA-256: f7f2882e0a7315fc532085d814fc54ea2a2fb4dc4778b61dda05261e1cf22d24
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: not recorded
Not assessed
The decision rule requires further expert review.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Cadmium
This measures a potential contaminant. Concentration, unit, detection limit and the applicable product category matter.
- Result as reported
- <0,010
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, ICP-MS:2010-04
- Source location
- Page 2
Reporting limit: 0.01 mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion · Page 2
Stated criterion: Höchstgehalt 1 mg/kg · mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
Applicability: reviewed · Attributed only to the original report's stated category and submitted sample. No independent current-law, other-product or current-retail-batch claim.
Criterion source ↗Source observation and document identity
Source observed: 2026-10-17T18:01:39.221Z
Content fetched: 2026-10-17T18:01:39.221Z
Page 2
SHA-256: f7f2882e0a7315fc532085d814fc54ea2a2fb4dc4778b61dda05261e1cf22d24
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: not recorded
Not assessed
The decision rule requires further expert review.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Quecksilber
This measures a potential contaminant. Concentration, unit, detection limit and the applicable product category matter.
- Result as reported
- <0,010
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, ICP-MS:2010-04
- Source location
- Page 2
Reporting limit: 0.01 mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion · Page 2
Stated criterion: Höchstgehalt 0,1 mg/kg · mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
Applicability: reviewed · Attributed only to the original report's stated category and submitted sample. No independent current-law, other-product or current-retail-batch claim.
Criterion source ↗Source observation and document identity
Source observed: 2026-10-17T18:01:39.221Z
Content fetched: 2026-10-17T18:01:39.221Z
Page 2
SHA-256: f7f2882e0a7315fc532085d814fc54ea2a2fb4dc4778b61dda05261e1cf22d24
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: not recorded
Not assessed
The decision rule requires further expert review.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Arsen
This measures a potential contaminant. Concentration, unit, detection limit and the applicable product category matter.
- Result as reported
- <0,040
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, ICP-MS:2010-04
- Source location
- Page 2
Reporting limit: 0.04 mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion · Page 2
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: not recorded
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Nickel
The measurement comes from the tested sample. Declared and measured amounts are directly comparable only with the same unit and basis.
- Result as reported
- 0,75
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, modified, ICP-MS:2010-04
- Source location
- Page 2
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: ±0,15 mg/kg; expanded combined uncertainty per DIN ISO 11352, k = 2 (95%); sampling excluded (sourceI,page 3).
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.
Aluminium
The measurement comes from the tested sample. Declared and measured amounts are directly comparable only with the same unit and basis.
- Result as reported
- 18
- Unit and basis
- mg/kg · mg/kg of submitted finished-product sample, Watson Magnesium 120 capsules, batch 96467; no serving or bottle conversion
- Method
- DIN EN 15763, modified, ICP-MS:2010-04
- Source location
- Page 2
Decision rule: Source rule y compares below-tolerance values without adjusting uncertainty; above-tolerance values have uncertainty subtracted. Without a conformity assessment, uncertainty is informational. · Page 3
Measurement uncertainty: ±3,6 mg/kg; expanded combined uncertainty per DIN ISO 11352, k = 2 (95%); sampling excluded (sourceI,page 3).
Not assessed
No reviewed comparison criterion is recorded.
An analytical detection does not automatically mean good quality. Results below a reporting limit are neither zero nor an overall pass.